LINK/2+®, miniLINK/2+, and microLINK/2+™

    Technical Specifications

    LINK/2+
    Module Slots:

    Up to 54

    Physical Configurations:
    Rack mounted only

    Size (External modules may increase base measurements.):
    Mainframe: 13.125 in. (33.3 cm) high by 19 in. (48 cm) wide by 20.25 in. (51.6 cm) deep; LTS Chassis: 13.125 in. (33.3 cm) high by 19 in. (48 cm) wide by 17.5 in. (44.8 cm) deep; Fan Housing: 5.25 in. (13.3 cm) high by 19 in. (48 cm) wide by 20.25 in. (51.6 cm) deep; Power Supply Chassis: 7 in. (17.8 cm) high by 19 in. (48 cm) wide by 20.25 in. (51.6 cm) deep

    Weight:
    Mainframe or LTS Chassis (without internal power supplies or modules): 24.5 lb. (11.1 kg); Typical Module: 2.5 lb. (1.1 kg); Fan Housing: 10 lb. (4.5 kg); Power Supply
    Chassis: 16.6 lb. (7.5 kg); Power Supply Module: 18.5 lb. (8.4 kg)

    AC Power Requirements:
    Each Mainframe: 100 ±10VAC at 12A, 115 ±10VAC at 12A, 200 ±20VAC at 6A, or 230 ±20 VAC at 6A, 47 to 68 Hz, single phase;
    Fan Assembly: 115 ±10VAC at 0.9A or 230 ±20VAC at 0.45A, 47 to 63 Hz, single phase;
    -48 VDCE & M Power Supply Module for certain E & M voice signaling types: 115±10VAC at 3A or 230 ±20VAC at 1.5 A, 47 to 68 Hz, single phase

    AC Power Consumption:
    1000 watts maximum per Mainframe;
    250 watts maximum per -48 VDCE & M Power Supply Module

    Heat Dissipation:
    3400 BTUs/hour maximum per Mainframe plus 850 BTUs/hour maximum per -48 VDCE & M Power Supply Module

    Optional -48 VDC Power Supply:
    Physical Configuration: Rack mounted only in power supply chassis
    Weight: 11 lb. (5 kg)
    AC Power Requirements: -48 VDC at 22A
    AC Power Consumption: 1,000 watts maximum

    miniLINK/2+
    Module Slots:

    13

    Physical Configurations:
    Rack mounted only

    Size (External modules may increase base measurements.):
    Mainframe: 13.125 in. (33.3 cm) high by 19 in. (48 cm) wide by 20.25 in. (51.6 cm) deep;
    Fan Housing: 3.5 in. (8.9 cm) high by 19 in. (48 cm) wide by 16.5 in. (41.9 cm) deep

    Weight:
    Mainframe (without internal power supplies or modules): 24.5 lb. (11.1 kg);
    Typical Module: 2.5 lb. (1.1 kg);
    Power Supply Module: 18.5 lb. (8.4 kg)

    AC Power Requirements:
    100 ±10 VAC at 12A, 15 ±10 VAC at 12A, 200 ±20 VAC at 6A, 230 ±20 VAC at 6A, 47 to 63 Hz; single phase

    AC Power Consumption:
    685 watts maximum

    Heat Dissipation:
    2330 BTUs/hour maximum

    microLINK/2+
    Module Slots:

    6

    Physical Configurations:
    Freestanding with case.
    Rack mounted without case.

    Size (External modules may increase base measurements.):
    With Case: 23.25 in. (59 cm) high by 8.375 in. (21.3 cm) wide by 24.75 in. (62.9 cm) deep;
    Floor Plate: 13.375 in. (34 cm) wide;
    Without Case: 22.75 in. (57.8 cm) high by 6.75 in. (17.1 cm) wide by 20.375 in. (51.8 cm) deep

    Weight:
    With Case: 60 lb. (27.2 kg);
    Without Case: 33 lb. (15.0 kg);
    Typical Module: 2.5 lb. (1.1 kg)

    AC Power Requirements:
    100 ±8 VAC at 5.5A, 115 ±10 VAC at 5A, 200 ±16 VAC at 3A, or 230 ±20 VAC at 2.5A, 47 to 63 Hz; single phase AC Power Consumption 280 watts maximum

    Heat Dissipation:
    958 BTUs/hour maximum

    Optional -48 VDC Power Supply:
    Physical Configuration: Rack mounted only in power supply chassis
    Weight: 11 lb. (5 kg)
    AC Power Requirements: -48 VDC at 22A
    AC Power Consumption: 1,000 watts maximum