LINK/2+®, miniLINK/2+, and
microLINK/2+
Technical Specifications
LINK/2+
Module Slots:
Up to 54
Physical Configurations:
Rack mounted only
Size (External modules may increase base measurements.):
Mainframe: 13.125 in. (33.3 cm) high by 19 in. (48 cm) wide by 20.25 in. (51.6 cm) deep;
LTS Chassis: 13.125 in. (33.3 cm) high by 19 in. (48 cm) wide by 17.5 in. (44.8 cm) deep;
Fan Housing: 5.25 in. (13.3 cm) high by 19 in. (48 cm) wide by 20.25 in. (51.6 cm) deep;
Power Supply Chassis: 7 in. (17.8 cm) high by 19 in. (48 cm) wide by 20.25 in. (51.6 cm)
deep
Weight:
Mainframe or LTS Chassis (without internal power supplies or modules): 24.5 lb. (11.1 kg);
Typical Module: 2.5 lb. (1.1 kg); Fan Housing: 10 lb. (4.5 kg); Power Supply
Chassis: 16.6 lb. (7.5 kg); Power Supply Module: 18.5 lb. (8.4 kg)
AC Power Requirements:
Each Mainframe: 100 ±10VAC at 12A, 115 ±10VAC at 12A, 200 ±20VAC at 6A, or 230 ±20 VAC
at 6A, 47 to 68 Hz, single phase;
Fan Assembly: 115 ±10VAC at 0.9A or 230 ±20VAC at 0.45A, 47 to 63 Hz, single phase;
-48 VDCE & M Power Supply Module for certain E & M voice signaling types:
115±10VAC at 3A or 230 ±20VAC at 1.5 A, 47 to 68 Hz, single phase
AC Power Consumption:
1000 watts maximum per Mainframe;
250 watts maximum per -48 VDCE & M Power Supply Module
Heat Dissipation:
3400 BTUs/hour maximum per Mainframe plus 850 BTUs/hour maximum per -48 VDCE & M Power
Supply Module
Optional -48 VDC Power Supply:
Physical Configuration: Rack mounted only in power supply chassis
Weight: 11 lb. (5 kg)
AC Power Requirements: -48 VDC at 22A
AC Power Consumption: 1,000 watts maximum
miniLINK/2+
Module Slots:
13
Physical Configurations:
Rack mounted only
Size (External modules may increase base measurements.):
Mainframe: 13.125 in. (33.3 cm) high by 19 in. (48 cm) wide by 20.25 in. (51.6 cm) deep;
Fan Housing: 3.5 in. (8.9 cm) high by 19 in. (48 cm) wide by 16.5 in. (41.9 cm) deep
Weight:
Mainframe (without internal power supplies or modules): 24.5 lb. (11.1 kg);
Typical Module: 2.5 lb. (1.1 kg);
Power Supply Module: 18.5 lb. (8.4 kg)
AC Power Requirements:
100 ±10 VAC at 12A, 15 ±10 VAC at 12A, 200 ±20 VAC at 6A, 230 ±20 VAC at 6A, 47 to 63
Hz; single phase
AC Power Consumption:
685 watts maximum
Heat Dissipation:
2330 BTUs/hour maximum
microLINK/2+
Module Slots:
6
Physical Configurations:
Freestanding with case.
Rack mounted without case.
Size (External modules may increase base measurements.):
With Case: 23.25 in. (59 cm) high by 8.375 in. (21.3 cm) wide by 24.75 in. (62.9 cm) deep;
Floor Plate: 13.375 in. (34 cm) wide;
Without Case: 22.75 in. (57.8 cm) high by 6.75 in. (17.1 cm) wide by 20.375 in. (51.8 cm)
deep
Weight:
With Case: 60 lb. (27.2 kg);
Without Case: 33 lb. (15.0 kg);
Typical Module: 2.5 lb. (1.1 kg)
AC Power Requirements:
100 ±8 VAC at 5.5A, 115 ±10 VAC at 5A, 200 ±16 VAC at 3A, or 230 ±20 VAC at 2.5A, 47
to 63 Hz; single phase AC Power Consumption 280 watts maximum
Heat Dissipation:
958 BTUs/hour maximum
Optional -48 VDC Power Supply:
Physical Configuration: Rack mounted only in power supply chassis
Weight: 11 lb. (5 kg)
AC Power Requirements: -48 VDC at 22A
AC Power Consumption: 1,000 watts maximum
Product Highlights & Overview
Manuals | MIBS