| PremNet® Synchronous/Asynchronous Interface Modules |
|
|
This PremNet® family of interface modules (V.35, RS232, and RS422) provides synchronous and asynchronous data communication and longdistance connectivity across the PremNet broadband access system. The PremNet system uses T3 (45 Mbps), Unilink (100 Mbps), SONET/SDH OC-3c/STM-1 (155 Mbps), and ATM OC3c/STM-1 (155 Mbps) technology to seamlessly connect V.35, RS-232, and RS-422 devices that are geographically dispersed by hundreds of miles.
Multipoint Without Extra Bandwidth
Using PremNet, these interface modules allow several connections to be on the same virtual
circuit. You can drop ports to different locations on the PremNet backbone network. The
PremNet matrix switch technology allows your multipoint synchronous/asynchronous
applications to share the same bandwidth (time-slot allocation) regardless of how many
drop-offs are configured.
Choice of Network Management Interface
The PremNet interface modules and the entire PremNet network can be managed from a variety
of network management platforms. You can choose to use existing Simple Network Management
Protocol (SNMP)-compliant network management system, the Milgo CMS 400 Management System,
or the PremNet local on-board management via an asynchronous terminal attached to any node
on the network.
The PremNet synchronous/asynchronous interface modules are network-managed, providing configuration, test and view/monitor capability on a port-by-port or module-by-module basis. Each port on a module can be independently software-configured.
DTE or DCE and Configurable Options
All three synchronous/asynchronous interface modules are software-configurable for either
DTE or DCE interface, allowing you to change the direction of the data from DTE to DCE or
vice-versa. The configuration options include DDS, Loopback, and Strap Control Line.
PremNet Asynchronous Multidrop Application
V.35 Interface Module
The PremNet V.35 interface module provides software-configurable data rates (up to 2.048
Mbps on each port). Each of the four Winchester (M34) ports on a module may be configured
independently.
The module has a total of six mappable control signals (three transmit and three receive), each with a software-configurable delay of up to ~24 msec. A built-in test-pattern generator also is included for enhanced diagnostics and maintenance.
RS-232 Interface Module
Milgo offers two versions of the PremNet RS232 interface module: 4 ports or 32 ports
with data rates of up to 19.2 Kbps.
Typical applications for the RS-232 module include machine control, remote sensing, and remote video camera control. Airports (throughout the United States and overseas) also use PremNet RS232 modules to transport low-speed telemetry and radar data.
Highway Monitoring - A transportation department uses a widely deployed PremNet fiber optic backbone network to monitor and control traffic in congested downtown areas of the city. Sensor pads (imbedded in roadway on-ramps and toll areas) can collect data as vehicles pass over them, reporting back to a 170 controller. The data (in RS-232 format) can then be transported across a PremNet fiber backbone ring to a central Traffic Control Center, where it is processed via a Digital Equipment Corporation VAX.
Remote Camera Control - A Traffic Control Center can use additional RS232 interface modules to remotely control dozens of video cameras mounted on roadway overpasses. Using the RS232 modules to transport all camera pan, tilt and zoom command functions, the Traffic Control Center can detect congestion problems and accidents immediately, improving safety and reducing accident response times.
Multidrop Capability, Full-Control Signals,
Low-Speed Telemetry
The 4-port version of the PremNet RS232 module offers multidrop functionality as well as
synchronous and asynchronous data transport via four standard RS-232 ports.
Full control-line signals - CTS, DTR, RTS, BSY, UNA, DSR, DCD, and RI - enable you to continuously monitor the activity of the control lines.
High Port Density
When multiple RS-232 connections are a major concern, the 32-port asynchronous module
offers unparalleled port density - you can connect as many as 32 terminals to a single
PremNet module. Each PremNet chassis (node) has slots for eight interface modules, and up
to 16 PremNet nodes can be connected in a single ring. A fully populated network can
support up to 4,096 RS232 connections.
On the 32-port version, the ports are distributed among 8 groups of 4 ports each. Each group can be software-configured independently; "loopback" mode allows groups to be dropped off at user-specified locations.
RS-422 Interface Module
The PremNet RS-422 module has four DB-25 ports with data rates that range from 56 Kbps to
2.048 Mbps on each port. With as many as eight modules in one node (chassis), up to 512
RS422 ports may be connected to a single PremNet ring.
The RS-422 interface module has a total of five mappable control signals (three transmit and two receive), each with software-configurable delay of up to ~24 msec. A built-in test-pattern generator is also included for enhanced diagnostics and maintenance capability.
RS-422 Module Configured as a DTE being clocked by the DCE
PremNet® Synchronous/Asynchronous
Interface Modules
Technical Specifications
RS-232 Module-Specific
| Part Numbers | PN850020:RS-232 interface module (4-port) PN850057:RS-232 interface module (32-port) |
| Ports/Connectors | 4-port version configured as DCE presented on DB-25 female connectors 32-port version is via 50-pin telco female connectors |
| Data Format | EIA-232C compliant |
| Data Rate/Timing Jitter | 19.2 Kbps + 2.7% for 4-port 19.2 Kbps + 2.7% for 32-port using two time slots |
| Clock Modes/Rates | Internal (six software-selectable), external, slave, and asynchronous
for 4-port version Asynchronous for 32-port version |
| Control Signals | Four each direction, with less than 6 msec delay (4-port version) |
| Bandwidth/Time Slot Requirements |
One PremNet time slot is required for an RS-232 point-to-point or multipoint virtual circuit |
RS-422 Module-Specific
| Part Number | PN 850022: RS-422 interface module |
| Ports/Connectors | Four DB-25 female connectors |
| Data Format | EIA-422 compliant |
| Data Rates/Timing Jitter | Internal Clock: 56, 64, 112, 128, 256, 384, 448, 512,
768, 772, 1,024, 1,536, 1,544, and 2,048 Mbps External Clock: 24.4 Kbps to 2.048 Mbps Asynchronous: 0 to 256 Kbps (maximum timing jitter ~3% at 64 Kbps sync) |
| Control Signals | Five (three transmit, two receive), with soft-configurable delay up to
~24 msec Control line delay <3 msec typical |
| Bandwidth/Time Slot Requirements |
One PremNet time slot is required for an RS-422 point-to-point or multipoint virtual circuit |
V.35 Module-Specific
| Part Number | PN 850023: V.35 interface module |
| Ports/Connectors | Four Winchester (M34) female connectors |
| Data Format | CCITT V.35 compliant |
| Data Rates/Timing Jitter | Internal clock: 56, 64, 112, 128, 256, 384, 448, 512,
768, 772, 1,024, 1,536, 1,544, and 2,048 Kbps External clock: 24.4 Kbps to 2.048 Mbps Asynchronous: 0 to 256 Kbps (maximum timing jitter ~3% at 64 Kbps sync) |
| Control Signals | Six (three transmit, three receive), with software-configurable delay
up to ~24 msec Control line delay <3 msec typical |
| Bandwidth/Time Slot Requirements |
One PremNet time slot is required for a V.35 point-to-point or multipoint virtual circuit |
RS-232, RS-422, and V.35 Modules
| LEDs | Three (alarm, standby, and active) on chassis |
| Configuration Maximum | Up to eight modules per node; 16 nodes per ring |
| Network Management | Managed via the standard PremNet integrated system, the Milgo CMS 400 Management System or SNMP-compliant network management |
| Environmental | Operating temperature: 32° to 122° F (0° to 50° C) Storage temperature: -40° to 158° F (-40° to 70° C) Humidity: 95% noncondensing |
Our policy of continuous development may cause the information and specifications contained herein to change without notice.
PremNet and CMS are registered trademarks of Milgo Solutions. All other logos and product names are trademarks or registered trademarks of their respective companies.
©1999 Milgo Solutions. All rights reserved. Printed in U.S.A.
3C1465 4/99